BATTERY RECHARGING
Rechargeable nicad batteries may take as many as 1,000
recharges, however they do have some limitations you should
be aware of:
1. Nicads will last only about half as long as
standard carbon-zinc batteries before
recharging is required.
2. Nicads may develop a “memory” if you give
them repeated “booster” charges. In other
words, if you charge your batteries over and
over again for only three hours at a time, the
Eight 1.5V size AA batteries are located in the rear section of
the Control Housing. The batteries are sealed off from the
electronics so that accidental water leakage into the battery
compartment will not damage the circuitry.
1. Remove the battery cover by partially
unscrewing the two knurled thumb screws with a
coin. (The knurled knobs are “captive screws” and
do not have to be completely removed from the
battery cover.)
2. Remove the battery pack from the Control
Housing and disconnect the battery lead
connector. Be very careful not to put any undue
strain on the battery leads.
3. Remove the batteries from the battery packs.
Note the polarity markings inside the pack and
install fresh batteries.
4. Reconnect the battery lead.
5. Insert the battery pack into the Control Housing
with the lead connector up, on the right side. Fold
the leads across the top of the pack.
6. Make sure the O-Ring and both sealing surfaces
are clean before reinstalling the battery cover. THIS
IS EXTREMELY IMPORTANT.
7. Finger tighten the thumb screws, then carefully
tighten again one-quarter turn with a coin.
BATTERY REPLACEMENT